ArcWriter plasma marking system
The ArcWriter® plasma power supply was last manufactured in December 2021, and is no longer available for sale from Hypertherm. We continue to make parts, consumables, and provide support for a period of seven to ten years after obsolescence.
System information
Product lifecycle
Affected power supply part numbers:
084009, 084010, 084004, 084015, 084018
AVAILABILITY | |
---|---|
Power supply | ⊗ |
Original torch | ✔ |
Service parts | ✔ |
Consumables | ✔ |
Technical support | ✔ |
Specifications
Power supply
Electrical Rated OCV Output Current Output voltage Duty Cycle at 40 C Input Voltage |
235 VCD at rated input voltage 4 - 19 amps, adjustable in 1-amp increments 120 VCD 100% (19 amps, 120 VCD) 200 V, 3 PH, 50-60 Hz 208 V, 3 PH, 60 Hz 240 V, 3 PH, 60 Hz 400 V, 3 PH, 50-60 Hz 440 V, 3 PH, 60 Hz 480 V, 3 PH, 60 Hz 600 V, 3 PH, 50-60 Hz |
Dimensions and Weight Depth Width Height Weight |
716 mm (28.2 inches) 321 mm (12.6 inches) 475 mm (18.7 inches) 55 kg (100 pounds) |
Gas Requirements Plasma Gas Shield |
Air or H5 (premixed industrial grade gas containing 5% Hydrogen and 95% Argon) Air |
Gas Quality Air H5 |
Clean, dry and oil-free 5% Hydrogen, 95% Argon premixed |
Flow Rates and Pressures Plasma Gas Shield Plasma |
28 I/min (60 scfh) @ 6.9 bar (100 psi) supplied to power supply pressure regulator 141 I/min (300 scfh) @ 6.9 bar (100 psi) supplied to power supply pressure regulator |
Plasma torch
Type | Dual Gas, Mechanized |
Gas | Plasma and Shield (refer to gas requirements) |
Starting Method | Contact start |
Cap Sensor | Pneumatic |
Dimensions and Weight Diameter Length Weight |
38.1 mm (1.5 inches) 280 mm (11 inches) 0.8 kg (1.5 pounds) |